Cathodic protection performance depends on more than the anode itself. Power equipment, measurement access, electrical continuity, isolation, reference electrodes, and field connections determine whether current can be delivered, measured, and interpreted reliably.
01Rectifiers & Power
Impressed-current systems use an external DC power source, commonly a transformer-rectifier, to convert available AC power into controlled DC output for the anode circuit and protected structure.
Output voltage and current are adjusted to provide the level of protective current the structure needs, while keeping the system within its design limits. Enclosures, meters, circuit protection, taps, controls, and remote-monitoring capability vary by installation.
02Test Stations
Test stations provide controlled field access to structure leads, reference-electrode leads, bonds, shunts, coupons, and other measurement points.
They support pipe-to-soil potential measurements, current measurements, bond checks, interruption testing, troubleshooting, and documentation without requiring direct access to buried conductors.
03Cables & Connections
CP cable, splices, terminations, junctions, and structure connections carry current and measurement signals through the system.
Connection integrity matters. High resistance, damaged insulation, poor terminations, broken leads, or loss of continuity can distort readings or reduce protection even when the rest of the system is operating normally.
04Isolation & Reference Components
Electrical isolation devices help control where protective current flows. Insulating joints, flanges, casings, bonds, and related components influence current distribution and interference behavior.
Reference electrodes provide the stable electrochemical reference used to evaluate structure-to-electrolyte potential. Electrode type and placement must match the environment and the measurement being made.
05Sensors & Remote Monitoring
Sensors and monitoring devices extend visibility beyond periodic field checks by capturing selected CP system conditions at installed measurement points.
Depending on the installation, monitored inputs can include rectifier voltage and current, structure-to-electrolyte potential, bond current, and other configured electrical measurements used to identify change and support follow-up.